Notifier SCS-8L Smoke Control Lamp Driver Master Module
| Brand | Notifier |
|---|---|
| SKU | SCS-8L |
| Type | Cards |
| Variants | 1 |
Notifier SCS-8L — Smoke Control Station lamp driver master module with eight switch groups, expandable to 16 with an SCE-8L expander, for a custom graphic smoke control annunciator.
SCS Series stations are used with the Notifier NFS2-3030 panel or the NCA-2 network annunciator for Firefighter's Smoke Control Station (FSCS) applications, and with the NFS-320, NFS2-640, NFS2-3030 and NCA-2 for HVAC applications. Each switch group controls and monitors a fan or damper, or a group of fans or dampers. The SCS-8L is the lamp driver version of the SCS-8: instead of on-board switches and LEDs, each group has contacts for a three-position switch and three lamps or LEDs mounted on the graphic.
Specifications
| Model | SCS-8L |
| Type | Smoke control lamp driver master module |
| Switch groups | 8 (16 with SCE-8L) |
| Modes | FSCS or HVAC |
| Communication | Two-wire EIA-485 annunciator circuit |
| Power | Separate 24 VDC regulated power loop |
| Addressing | Two rotary decimal switches; eight DIP switches for mode |
| System capacity | Up to 32 annunciator addresses, 512 switch groups |
| Operating temperature | 32°F to 120°F (0°C to 49°C) |
Installation notes
- The SCS-8L must be installed in a UL-approved custom graphic annunciator panel and backbox
- Each group connects a three-position switch and three lamps or LEDs; the module also drives two LEDs and one momentary switch
- HVAC mode is for fan shutdown and building HVAC only and is not consistent with UL and NFPA smoke control standards
- Loss of the 24 VDC power loop causes a trouble at the control panel
Related models
- SCS-8: smoke control module with on-board switches and LEDs
- SCE-8L: lamp driver expander adding eight more groups
FAQ
What is the difference between the SCS-8 and SCS-8L?
The SCS-8 has on-board toggle switches and LEDs. The SCS-8L is the lamp driver version, with contacts for remote switches and lamps or LEDs on a custom graphic annunciator.
Which panels work with it?
The NFS2-3030 or NCA-2 for Firefighter's Smoke Control Station applications, and the NFS-320, NFS2-640, NFS2-3030 and NCA-2 for HVAC applications.
How many fans or dampers can one module handle?
Eight switch groups, or 16 with an SCE-8L expander. Up to 32 annunciator addresses give a system maximum of 512 switch groups.
How is it powered?
From a separate 24 VDC regulated power loop, with communication over a two-wire EIA-485 circuit.
Questions about this product
Is Notifier SCS-8L Smoke Control Lamp Driver Master Module in stock?
Yes — 49 units are available and ready to ship from our US warehouse.
How fast will Notifier SCS-8L Smoke Control Lamp Driver Master Module ship?
Orders placed before 3:00 PM ET ship the same business day. Delivery takes 3–5 business days inside the USA.
Where does Notifier SCS-8L Smoke Control Lamp Driver Master Module ship from?
It ships from the United States. Standard delivery is 3–5 business days, and orders placed before 3:00 PM ET go out the same day.